IEC60335-1 Temperature Rise Black Test Corner with K Type Thermocouple for Household Appliance
1. Introduction
The Black Test Corner is used for the measurement of the temperature radiated by different equipment during the tests from heating and abnormal operation. One is designed and made with the intention of determining the fulfillment of different standards as far as the registry from temperatures during the operation of the apparatus under test.
The Black Test Corner is conformed by a trihedral or tetrahedron one of black painting plywood, with a matrix of holes each 100 mm that allow to adapt thermocouples of measurement easily, specially designed for such case.
The dimensions of the device are: base 1000mm x 1000mm and with a height of 1000mm, includes two side plates, one bottom and one top plate, the top plate can be removed, bottom plate mounted on a structure with wheels, to allow his movement.
Thermocouples of measurement is of curved type K ( Ø0.3mm), mounted on terminal block, and in its end of measurement they have a copper disc of Ø15 mm and 1 mm of thickness. The amount of thermocouples is according to the necessity of the client.
2. Parameters
Material | Plywood 20mm of thickness,painted with matt black paint on the front, gray-white film board attached on the back |
Measurement points |
136 points, includes cooper disc (Ø15 mm, 1mm thickness), thermcouple points: 100mm*100mm (square), start from inner corner |
Thermocouples |
Cable length: 2m Type: K type Diameter: less than Ø0.3mm |
Dimension | 1000mm*1000mm*1000mm (L*W*H) |
Warranty | 12 months |
Standard | IEC 60335-1 / Clause 11 |