Brief

UL94,50W and 500W Horizontal-Vertical Flame Tester When there is a fire around the products, should ensure that it will not to cause the spread of the fire


UL94,50W and 500W Horizontal-Vertical Flame Tester  A detailed description of
UL94,50W and 500W Horizontal-Vertical Flame Tester  

 1.Overview:
When there is a fire around the products, should ensure that it will not to cause the spread of the fire, horizontal-vertical burning test simulates electronic products around the environment in the early condition, using the simulation technology to assess the fire risk. The test equipment apply to the electrical and electronic product components of household appliances, spare parts and components, such as: household appliances insulation shell, Panel switches, printed circuit boards and insulation materials and so on.

2.Characteristics:

Horizontal-vertical flame chamber tester is composed by the test part and control part, using the integrated design, to facilitate the installation at the scene and debug. The shell of the test chamber and the important parts are all manufactured by stainless steel, resistant cigarettes and gas corrosion. The automatic degree of control system is high. Has automatic ignition, the products which were tested in both vertical and horizontal orientation has the function automatically follow flame in the cross of the test. Time and temperature figures show, so that the observation and records is facilitate and the use of it is stable and reliable.

 
3.Power supply:
AC220V±10%/50Hz.(Other power specifications can be customized).

 4.Technical Paremeters:

 

Kinds

  500W(5V class )  50W(HB/Vclass)
Parameters    
Test Flame 500W(burning test for V-0,V-1,V-2  classification)

50W(burning test for V-0,V-1,V-2 classification)

Burner Tube Internal diameter: Φ 9.5mm±0.3mm

Internal diameter: Φ 9.5mm±0.3mm, 

Burning Angle 0°,20°,45°

0°,20°,45 °

Thermocouple Type K (Ni/Cr - Ni/Al)

Type K (Ni/Cr - Ni/Al)

Thermocouple Size  0.5 mm

0.5 mm

Standard Copper Block  Φ9mm±0.01mm,weight:10g±0.05g before drilling.  

Φ5.5mm±0.01mm, weight.:.76g±0.01g before drilling. 

Time for Temperature to Increase From 100°C±5°C to 700°C±3°C; 54s±2s (preset)

From 100°C±5°C to 700°C±3°C;44s±2s (preset)

Gas Flow 965±32ml/min

105±10ml/min

Gas Supply methane,min.98% purity

methane,min.98% purity

water-column  125m±5mm

‹10mm

Test  Time 54±2s

44±2s

Flame Height Indicator 40±1mm

20±1mm

Volume Of Chamber >0.5m³, black interior

>0.5m³, black interior

Outer Dimensions W*D*H=1100mm*550mm*1300mm

W*D*H=1100mm*550mm*1300mm

Conform to standard UL94,IEC60695-11-3,IEC60695-11-20

UL94,IEC60695-11-4,IEC60695-11-10

 

Leave a message for product
Title
Contact
Tel
Content
Verify Code
Click to change
Note:1. Shortcut key for send message :Alt+s or Ctrl+Enter!
2. If necessary, please leave your detail contact!
Leave a message for product
Title
Contact
Tel
Email
Content
Verify Code
               
Note:1. Shortcut key for send message :Alt+s or Ctrl+Enter!
2. If necessary, please leave your detail contact!

粤公网安备 44030602001691号