Product Details
  • Product name:salt spray test chamber for corrsion testing

  • Product number:CX-60L
  • Product manufacturer:Chuangxin
  • Product documentation:
你添加了1件商品 查看购物车
a brief introdction:
salt spray test chamber for corrsion testing High-precision temperature controller,Japan OML timer to control time, the overall temperature error of ± 1°c
Details description:

salt spray test chamber for corrsion testing

 

1.Technical parameters:

Model CX-60 CX-90 CX-120

Inner  Box Size

 (W*D*H)  mm   

600*450*400      900*600*500   1200*800*500      
Outsider Box Size(W*D*H) mm  1070*580*1030 1380*800*1150 1700*950*1210
Testing capacity  108L  270L  480L
Power 220V,1.5KW ,50HZ 220V,1.5KW ,50HZ 220V,3KW,50HZ

 

2. Technical Features:

Box material :   Local temperature and humidity inside and outside the box are used for A-level gray high-corrosive PVC, for salt spray, copper acetate, and other test specifications Test

  • Saturation pressure barrel :   It uses the A-level German imports of gray PVC material.
  • Laboratory Racks:  It uses sophisticated Class A gray PVC material designed "V" shape long, products tested by the 15 ° -30 ° angle be adjusted.
  • Laboratory cover:It uses a 5mm thick transparent imported high toughness PVC board, bending method designed to cover 100 degree ridge-type transparent
  • With power failure memory function of time, so after the original call time to complete the remaining time of the experimental work, with a double over-temperature protection, water shortage warning, ensure safety
  • Technical basis:According to JIS, ASTM, CNS, GB standard parameter setting operation.
   Standard   Laboratory  Air pressure barrel
 Salt spray test  NSS ,ACSS   35°C±1°C  47°C±1°C
 Corrosion test  CASS   50°C±1°C  63°C±1°C

 

3. Systems:

Heating system

It uses steam heating, heating speed, reduce the standby time, when the temperature reached, the thermostat automatically switches the state, the temperature accuracy, less power consumption

 

•Control system

High-precision temperature controller, Japan OML timer to control the time, the overall temperature error of ± 1°c