IEC 62368 Test Equipment
- IEC60529 IP CODE TESTING...
-
IEC60335-1 Testing equip...
-
Flammability Test Chambe...
-
IEC60884-1Testing Equipm...
- Accessibility Probes
-
Impact Testing
-
IEC60061-3 lamp gauge
-
Electric Safety Tester
-
Environment Test Chamber
-
UL Testing equipment
-
LED Test Instruments
-
Plug, Socket & Switch Te...
-
Oscilloscope
-
Electronic Components Te...
-
Force Meter
-
Tensile Testing Machine
-
Other product
-
Plug and Socket Gauges
0.3M integrating sphere for leds luminous flux test
1、 System
Functions
The system are composed of integrating sphere, spectroradiometer and computer to determine the spectroradiometric and colorimetric parameters, e.g. spectral power distribution, chromaticity coordinates, correlated color temperature, color rendering index, color tolerance, color difference, luminous flux, current, voltage, wattage, etc.Standards:
1) Solid-State Lighting Program Requirements
2) LM-79
3) CIE127
2、 Technical indicators:
1)SPEC1000A Rapid Spectroradiometer
Spectral range: 380nm ~ 780nm
Measurement speed: rapid speed 3ms~2000ms
Measuring Devices: high-sensitivity CCD imported
Wavelength accuracy: 0.3nm
Wavelength repeatability: 0.2nm
Photometric linearity: 0.5%
Color temperature range: 1500K ~ 30000K
Photometric range(lumens):0.01lm-1.9999×105 lm
Color coordinates accuracy: 0.0008 (Standard light source)
2)1.2m Optical Fiber
u Length: 1.2m
u Diameter: 0.4mm
u Interface dimensions: SMA905
3)0.3m Integrating Sphere
u Diameter:0.3m
u Fine diffuse reflection. Reflectance ρ≈0.93,BaSO4;
u For Power LED,SMD LED
u Entrance port: Φ30mm or customized
u Measurement method: center 4π
u Equipped with baffle for sensor
Single LED Test Fixture
u With 0.5m integrating sphere
u Used for SMD LED(3014,3528,5050)
u Power LED 1W, 3W
u MR16, etc
4)Standard Lamp 10W
u Sectral range : 380 ~ 780nm continuous spectrum ;
u Germany OSRAM;
u Life :2000 h ;
u DC constant current mode ;
u Color temperature 2856K;
u Color Temperature Stability : 0.2% ;
u Flux stability: 0.2% ;
5)LCP-3005 CC & CV DC Power Supply (30V/5A)
u Output:30V,5A
u Source / Load effect:
(1) Regulator CV ≤ 5 * 10-4 +1 mV
(2) Steady flow CC ≤ 1 * 10-4 +2 mA
u Rripple factor:
(1) Regulator CV ≤ 1.5mV