IEC 62368 Test Equipment
- IEC60529 IP CODE TESTING...
-
IEC60335-1 Testing equip...
-
Flammability Test Chambe...
-
IEC60884-1Testing Equipm...
- Accessibility Probes
-
Impact Testing
-
IEC60061-3 lamp gauge
-
Electric Safety Tester
-
Environment Test Chamber
-
UL Testing equipment
-
LED Test Instruments
-
Plug, Socket & Switch Te...
-
Oscilloscope
-
Electronic Components Te...
-
Force Meter
-
Tensile Testing Machine
-
Other product
-
Plug and Socket Gauges
Tracking Index Testing Equipment
It applied with rectangle size of platinum electrode, each electrode can force to the sample is 1.0±0.05N
Electrode Distance: 4.0mm±0.01mm, included angle: 60°±5°
Electrode Voltage: 100~600V, (48~60HZ) adjustable, when the
short-circuit current at 1.0±0.1A, the voltage goes down less than 10%
The
liquid drop device can make the liquid height from 30~40mm
(adjustable), drops liquid size is 44~55 drops/1cm3. The interval drops
of liquid is 30s±5s (adjustable)
During
the testing, the short-circuit current is more than 0.5A to keep 2
seconds, then shut off current, it show the sample not pass. Inside
dimension: 0.5CBM and outside dimension: 630mm*390mm*750mm