Product Navigation
-
IEC 62368 Test Equipment
- IEC60529 IP CODE TESTING...
-
IEC60335-1 Testing equip...
-
Flammability Test Chambe...
-
IEC60884-1Testing Equipm...
- Accessibility Probes
-
Impact Testing
-
IEC60061-3 lamp gauge
-
Electric Safety Tester
-
Environment Test Chamber
-
UL Testing equipment
-
LED Test Instruments
-
Plug, Socket & Switch Te...
-
Oscilloscope
-
Electronic Components Te...
-
Force Meter
-
Tensile Testing Machine
-
Other product
-
Plug and Socket Gauges
Product Details
a brief introdction:
IEC 62368-1 Clause 5.4.1.5.3 Heating Chamber For Ball Pressure Test
Details description:
Product information:
This heating chamber is required by IEC 62368-1:2018 clause 5.4.1.5.3, 5.4.1.10, Annex G.5.3.4, Annex G.13.6.2, Annex M.4.2, M.4.4.4, Annex. P.4, Annex T.8, IEC60950:2013 clause 2.10.8.2, clause 4.2.7, clause 4.5.5, clause 4.7.3.2, IEC 60695-10-3 etc.
Features:
1. The drying oven must be good grounded to ensure safe.
2. The drying oven should be placed in a room with good ventilation conditions and no
inflammable and explosive materials or toxic substances around it.
3. There is no explosion-proof device in the drying oven, don’t put inflammable and
explosive materials into it for drying.
4. Do not overcrowd the objects in the oven, especially around the temperature sensor, make room for hot air circulation.
5. Do not wipe the machine surface with acid or alkali or corrosive substances. The inside
and outside of the drying oven should be kept clean. If it is not used for a long time, cover
it correctly and put in a dry room. If any abnormality in use, please cut off the power supply
and contact us in time.
6.Be careful of scalding when using in high temperature.
Technical Parameters:
Applied Standard IEC 62368-1
Clause 5.4.1.5.3, 5.4.1.10
Power supply AC 220V, 50Hz
Temperature Range RT+10°C ~300°C
Display Resolution 0.1°C
Temperature Fluctuation ±1°C
Power Rating 2600 W
Temperature Uniformity ±2.5°C
Display Method LCD screen
Volume / Working Area Size (W* D* H) 50cm*60cm**75cm
Outer Dimensions (W* D* H) 70cm*71cm*110cm
Communication Interface R485 interface on the right side of the device
Structure Type Vertical
This heating chamber is required by IEC 62368-1:2018 clause 5.4.1.5.3, 5.4.1.10, Annex G.5.3.4, Annex G.13.6.2, Annex M.4.2, M.4.4.4, Annex. P.4, Annex T.8, IEC60950:2013 clause 2.10.8.2, clause 4.2.7, clause 4.5.5, clause 4.7.3.2, IEC 60695-10-3 etc.
Features:
1. The drying oven must be good grounded to ensure safe.
2. The drying oven should be placed in a room with good ventilation conditions and no
inflammable and explosive materials or toxic substances around it.
3. There is no explosion-proof device in the drying oven, don’t put inflammable and
explosive materials into it for drying.
4. Do not overcrowd the objects in the oven, especially around the temperature sensor, make room for hot air circulation.
5. Do not wipe the machine surface with acid or alkali or corrosive substances. The inside
and outside of the drying oven should be kept clean. If it is not used for a long time, cover
it correctly and put in a dry room. If any abnormality in use, please cut off the power supply
and contact us in time.
6.Be careful of scalding when using in high temperature.
Technical Parameters:
Applied Standard IEC 62368-1
Clause 5.4.1.5.3, 5.4.1.10
Power supply AC 220V, 50Hz
Temperature Range RT+10°C ~300°C
Display Resolution 0.1°C
Temperature Fluctuation ±1°C
Power Rating 2600 W
Temperature Uniformity ±2.5°C
Display Method LCD screen
Volume / Working Area Size (W* D* H) 50cm*60cm**75cm
Outer Dimensions (W* D* H) 70cm*71cm*110cm
Communication Interface R485 interface on the right side of the device
Structure Type Vertical
Related Products