Article details

IEC61032 and IEC60529 IP1X Test Probe a difference

日期:2024-05-08 05:45
浏览次数:41
摘要:IEC61032 and IEC60529 IP1X Test Probe a with 50mm Steel Ball difference
 IP1X Test Probe a with 50mm Steel Ball

1. Reference Standard:
IEC60529,IEC61032,IEC60335,IEC61029,IEC60745,IEC60065,IEC60950.
 
2. Application:

This probe is intended to verify protection of persons against access to hazardous parts for an IP1 Code. Also used to verify protection from access with the back of the hand for an IP suffix A code.The handle is made of plastic and the ball is made of stainless steel.
 
3. Technical Parameter:

Ball diameter 50mm
Baffle plate diameter 45mm
Baffle plate thickness 4mm
Handle diameter 10mm
Handle length 100mm
Material plastic(delrin) + stainless steel
Reference Standard IEC61032 IEC60529 IEC60065 