IEC 62368 Test Equipment
- IEC60529 IP CODE TESTING...
-
IEC60335-1 Testing equip...
-
Flammability Test Chambe...
-
IEC60884-1Testing Equipm...
- Accessibility Probes
-
Impact Testing
-
IEC60061-3 lamp gauge
-
Electric Safety Tester
-
Environment Test Chamber
-
UL Testing equipment
-
LED Test Instruments
-
Plug, Socket & Switch Te...
-
Oscilloscope
-
Electronic Components Te...
-
Force Meter
-
Tensile Testing Machine
-
Other product
-
Plug and Socket Gauges
HC-210 Series Handheld Digital Thickness Gauges
HC series of coating thickness gauge is a portable thickness gauge with eddy current thickness method and electromagnetic thickness method. It can be used to quickly and accurately measure the thickness of coating or cladding material without damaging it. As an essential instrument for professional material protection,this coating thickness gauge is widely used in manufacturing industry, metal processing industry, chemical industry and commodities inspection etc.,both in the laboratory and in the engineering field. It can measure the thickness of nonmagnetic layer on magnetic metal substrate condition (such as steel, iron, alloy and hard magnetic steel, etc.) and the thickness of conductive layer on nonmagnetic metal substrate condition (such as rubber, paint, plastic, anodic oxidation film, etc.).
Main Characteristics:
1. With both the magnetic and eddy current thickness method, as well as measuring the thickness of the magnetic non-magnetic coating on metal substrates can measure the non-magnetic again the thickness of the conductive coating on metal substrates;
2. Two measuring methods: CONTINUE and SINGLE;
3. Two working modes: direct mode and burst mode;
4. With five statistics:MEAN,MAX,MIN,NOS.DEV;
5. Two methods can be used together for calibration, basic calibration method and can be used to modify the system error of measuring head;
6. With functions of storage:in storage 500 observed value;
7. Delete function: can delete the single suspicious measurement or the all storage data in order to start a new measurement;
8. To set boundaries:the measured value beyond the limit alarm automatically; And can be used histogram analysis of a batch of measurements;
9. Have print function: can print measurement, statistics, limit, histogram;
10. Can be communicated with a PC: Measurements, statistical values can be transmitted to the PC, so that the data can be further processed;
11. With low supply voltage indication function;
12. Operation works with beep prompt;
13. Has the error function, through onscreen or beep error message;
14. There are two shutdown modes: manual shutdown mode and automatic shutdown mode;
15. Dimension:147×65×30mm
16. Weight:0.2kg
Series spec parameters
Measuring head type |
HC-210(Magnetism F) |
HC-220 (Eddy current N) |
HC-200(Global function FN) |
|
|
|
|||||
Operating Principle |
Magnetic induction |
Whirlpool |
Magnetic induction+whirlpool |
|
|
|
|||||
Measurement Range(µm) |
0~1250 |
0~1250 |
0~1250 |
|
|
Lower limit of resolution(µm) |
0.1um(0-100),1um(100-1250) |
|
|||
Display NO. |
Background, the four books, according to two lines of statistics show |
|
|||
Calibration |
Manufacturer for the calibration, zero calibration, the calibration foil calibration |
|
|||
Display NO. |
One point calibration(µm) |
±(3%H+1) |
±(3%H+1.5) |
±(3%H+1)±(3%H+1.5) |
|
Two point calibration(µm) |
±[(1~3%H)+1] |
±[(1~3%H)+1.5] |
±[(1~3%H)+1]±[(1~3%H)+1.5] |
|
|
Test Strip |
Minimum radius of curvature(µm) |
Convexity 1.5mm,Camber concave 3mm |
|
||
Diameter of the minimum value(mm) |
Φ7 |
Φ5 |
Type FΦ7,Type NΦ5 |
|
|
Critical thickness of substrate(mm) |
0.5mm |
0.3mm |
Type F 0.5mm,Type N0.3mm |
|
|
|
|||||
Operating Environment |
Temperature:0℃-40℃ |
|
|||
Humidity:20%RH-90%RH |
|
||||
Without a strong magnetic field environment |
|
||||
Overall Dimension |
147×65×30 |
|
Probe selection parameters
|
Coating |
Organic materials and other non-magnetic coating (such as: paint, coatings, plastics, enamel and anodized, etc.) |
Non-magnetic non-ferrous metal layer (such as: chromium, zinc, aluminum, copper, tin, silver, etc.) |
Matrix |
|
||
Magnetic metals such as iron and steel |
F type probe |
F type probe |
|
Such as copper, aluminum, brass, tin, zinc and other non-ferrous metals |
N type probe |
N type probe is used only for chromium plating on the copper |