IEC 62368 Test Equipment
- IEC60529 IP CODE TESTING...
-
IEC60335-1 Testing equip...
-
Flammability Test Chambe...
-
IEC60884-1Testing Equipm...
- Accessibility Probes
-
Impact Testing
-
IEC60061-3 lamp gauge
-
Electric Safety Tester
-
Environment Test Chamber
-
UL Testing equipment
-
LED Test Instruments
-
Plug, Socket & Switch Te...
-
Oscilloscope
-
Electronic Components Te...
-
Force Meter
-
Tensile Testing Machine
-
Other product
-
Plug and Socket Gauges
Laboratory Salt Spray Corrosion Test Chamber
Introduction:
Laboratory Salt Spray Corrosion Test Chamber for Nss / Acss / Cass Test is used to test the anti-erosion quality of the surface of all materials after the rust-proof of painting, coating, electroplating, anoding and rust-proof of greasing.anti corrosion treatment for a variety of materials, corrosion resistance of their products.
1.Laboratory Salt Spray Corrosion Test Chamber for Nss / Acss / Cass Test is is made of transparent materials so that the operator can see the tested sample in it and the spraying situation of the tested sample.
2. A waterproof structure is adopted between the chamber cover and chamber body, thus there is no salt spray overflow.
3.Adopts the tower spraying system and equipped with the salt solution filter system and non-crystal nozzle so as to realize even salt spray distribution and freely adjustable settlement.
4.Control System High precision P.I.D. temperature control meter with its error ±0.1°C.
Model |
CX-Y60L |
CX-Y90L |
CX-Y120L |
CX-Y160L |
CX-Y200L |
Inner Size (cm) |
60*45*40 |
90*60*50 |
120*80*50 |
160*100*50 |
200*1200*60 |
External Size (cm) |
107*60*118 |
141*88*128 |
190*110*140 |
230*120*140 |
270*150*150 |
Inside Temp |
Brine test method (NSS ACSS) 35℃±1℃/Corrosion resistance test method (CASS) 50℃±1℃ |
||||
Brine Temp |
47℃±1℃/63℃±1℃ |
||||
Test Chamber Volume |
108L |
270L |
480L |
800L |
1440L |
Brine Chamber Volume |
15L |
25L |
40L |
40L |
40L |
Compressed Air Pressure |
1.00±0.01kgf/cm2 |
||||
Spray Volume |
1.0~2.0ml/80cm2/h (Collect at least 16 hours, the average) |
||||
Test Room Relative Humidity |
85% RH or more |
||||
PH |
6.5~7.2 or 3.0~3.2 |
||||
Spray Method |
Programmable spray (including the continuous spray interrupted spray) |
||||
Power |
AC220V1Φ10A |
AC220V1Φ15A |
AC220V1Φ20A |
AC220V1Φ20A |
AC220V1Φ10A |
Fetures:
*Automatic / manual water system has automatically add the water level of the water level is low, the test is not interrupted. Water level is insufficient warning to ensure that the use of safety.
*Spray tower attached to the conical dispersion, with oriented fog, the function of regulating the amount of fog and uniform loading amount of fog.
*The saturated air barrel using Henry's law, be heated humidification, and provide the required humidity of the laboratory. Its made of SUS # 304 stainless steel insulation effect, with visual connectivity and drainage switch, in order to visually saturated air the barrel water level and cleaning.
*Laboratory sealing cover material for Taiwan imported PVC board, pneumatic cylinder automatic lifting way, easy to operate safe and reliable.
Corresponding Standard:
GB11158 GB10589-89 GB10592-89 GB/T10586-89
GB/T2423.22-2001 GB/T2423.1-2001 GB/T2423.2-2001 GB/T2423.3-93
GB/T2423.4-93 ASTM D1735 ASTM D1735 IEC60068-2-1.1990
IEC60068-2-2.1974 IEC 68-2-30 IEC68-2-03 EIA - 364-31C EIA - 364-59