Product Details
  • Product name:IEC 60335-1 Rigid Finger Test Probe 11 With Force 75N

  • Product number:CX-11
  • Product manufacturer:Chuangxin
  • Product documentation:
你添加了1件商品 查看购物车
a brief introdction:
IEC 60335-1 Rigid Finger Test Probe 11 With Force 75N Product Information For Rigid Finger Test Probe 11: This rigid finger probe conforms to the standard requirement of IEC IEC60335-2-6 clause 22, IEC60335-2-9 clause 22, IEC61032 figure 7 device 11, IEC60884-1, IEC60598-1, IEC60335-1 Clause 22.11, etc. It is used to verify the protection of persons against access to hazardous parts, and to ver
Details description:

IEC 60335-1 Rigid Finger Test Probe 11 With Force 75N 

Product Information For Rigid Finger Test Probe 11:

This rigid finger probe conforms to the standard requirement of IEC IEC60335-2-6 clause 22, IEC60335-2-9 clause 22, IEC61032 figure 7 device 11, IEC60884-1, IEC60598-1, IEC60335-1 Clause 22.11, etc. It is used to verify the protection of persons against access to hazardous parts, and to verify the mechanical strengthen of openings in the enclosure or internal barriers.
This probe has provision to apply the force 0~75N with minimum resolution of 5N provided with alligator clip at back side for checking the continuity during the test. The finger part of this probe is made of stainless steel, the handle part and stop face are made of Nylon.

 

Technical Parameters For Rigid Finger Test Probe 11:

 

Probe Tip Length (mm) 20 0 -0.05
Probe Tip Cylindrical Radius (mm) R2±0.05
Probe Tip Spherical Radius (mm) R4±0.05
Probe Tip Cylindrical Angle (°) 37o 0 -10’
Probe Tip Spherical Angle (°) 14 o 0 -10’
Probe Diameter (mm) Ф12 0 -0.05
Probe Length with Tip (mm) 80±0.2
Sphere Probe Material Stainless Steel
Guard Diameter (mm) Ф50
Guard Thickness (mm) 5±0.5
Handle Material Nylon
Force Range 0~75N
Overall Resolution 5N
 

Test Procedures and Operation For Rigid Finger Test Probe 11:

Please refer to the relevant standards.

Push the upper surface of the handle to the required force scale line, then required force is achieved.

For verifying whether LIVE PARTS touched, the probe is equipped with an alligator clip, recommended to work with our anti-shock probe experiment device or a 40~50V voltage indicator.



粤公网安备 44030602001691号