Product Details
  • Product name:UV Weathering Test Chamber

  • Product number:CX-LU30
  • Product manufacturer:Chuangxin
  • Product documentation:
你添加了1件商品 查看购物车
a brief introdction:
UV Weathering Test Chamber ASTMG53-77, GB, GJB, MIL, ASTM, CNS, IEC, JIS, AATCC, DIN, Fed Test, BS, SAE and etc. Samples and Restrictions: Coating, ink, paint, resin, plastic, printing and packaging, aluminum profiles, adhesives, automobile and motorcycle components, cosmetics, metal, electronics, electroplating, medicine, etc.
Details description:


UV Weathering Test Chamber 

Standards & Clauses:

ASTMG53-77, GB, GJB, MIL, ASTM, CNS, IEC, JIS, AATCC, DIN, Fed Test, BS, SAE and etc.

 

Samples and Restrictions:

Coating, ink, paint, resin, plastic, printing and packaging, aluminum profiles, adhesives, automobile and motorcycle components, cosmetics, metal, electronics, electroplating, medicine, etc.

 

Application:

In the UV ultraviolet accelerated aging tester, the fluorescent UV lamps can reproduce the influence of sunlight, condensation and water sprinkler systems reproduce the effects of dew and rain. Temperature is controllable throughout the test cycle. Typical test cycle includes ultraviolet light irradiation at high temperature and relative humidity at 100% dark humid condensation; typical applications in paints, automotive, plastics, wood, glue, etc.

Structure:

UV Weathering Environmental Test Chamber Ultraviolet Accelerated Aging Test 0

Features:

 

The inner and outer casing is made of high-quality stainless steel, and the sample holder is composed of an aluminum alloy base lining plate and stretching springs.

 

The main controller is an intelligent digital display controller, easy for operation.

 

The input adopts digital correction system, built-in common thermocouple, the measurement is accurate and stable.

 

With position adjustment , AI artificial intelligence adjustment function, multiple alarm modes

 

Although ultraviolet light (UV) accounts for only 5% of sunlight, it is the main illuminating factor for the decline of outdoor durability, because the photochemical reaction of sunlight increases with the decrease of wavelength, therefore, when simulating the damage of sunlight to the physical properties of materials, it is not necessary to reproduce the entire sunlight spectrum, only necessary to simulate short-wave UV light.

 

The reason for using UV lamps is because they are more stable than other tubes and can better reproduce the test results.

 

Adopts fluorescent UV lamps to simulate the effects of light on physical properties, such as brightness reduction, fading, spalling, etc.. UVA-340 is the high-quality choice of simulating sunlight UV.

 

UVA-340 is an excellent simulation of the critical short-wavelength wavelength range of the solar spectrum, that is, the spectrum with a wavelength range of 295 to 360 nm. UVA-340 only produces a spectrum of UV wavelengths that can be found in sunlight.

 

UVB-313 is used for maximum accelerated testing and UVB-313 can quickly provide test results. The short-wavelength UV used is more intense than the UV light waves currently found on the Earth's surface. Although these UV light which is much shorter than the natural wavelength, can accelerate the test to the maximum extent.

 

Exposure method: steam condensation.

After the specified irradiation time, then transfer to the non-irradiated state of the simulated nighttime. At this time, the surface of the sample is still heated by the saturated mixture of hot air and water vapor in the exposed room, and the back side of the sample continues to be subjected to the surrounding space. The air is cooled to form an exposed state of condensation on the surface of the sample.

 

Ultraviolet radiation sensor (optional).

 

The UV aging test chamber is equipped with an ultraviolet radiation sensor, which is a high-precision photometric control system that allows the user to select the desired illuminance, continuous monitoring of the light intensity.

 

UV Weathering Environmental Test Chamber Ultraviolet Accelerated Aging Test 1

Technical Parameters:

Working Dimensions 1140mm*400mm*380mm External Dimensions 1300mm*500mm*1460mm
Condensation Temperature Range 40 ° C ~ 60 ° C / temperature tolerance ± 3 ° C Illumination Temperature Range 50 ° C ~ 70 ° C / temperature tolerance ± 3 ° C
Center Distance of the Lamp 70mm Temperature Control Method PID self-tuning temperature control mode
Temperature Resolution 0.1℃ Humidity Range About 45%~70% R.H
Wavelength Range

UV-A wavelength range is 315~400nm

UV-B wavelength range is 280nm~320nm 

Sink Request Water depth is not more than 50mm, and there is automatic water supply controller
Radiation Intensity Within 1W/m2/340nm Standard Test Piece Size 75×150mm 48pcs
The Closest Parallel Surface Distance from the Test Piece to the Surface of the Lamp Around 50mm Recommended Use Environment 5~35°C, 40%~85%RH, 300mm away from the wall
Blackboard Thermometer Measurement Range 30~80°C/tolerance is ±1°C Voltage 220V±5%, single-phase three-wire, 50Hz, 10A, requires 15A leakage switch



粤公网安备 44030602001691号