IEC 62368 Test Equipment
- IEC60529 IP CODE TESTING...
-
IEC60335-1 Testing equip...
-
Flammability Test Chambe...
-
IEC60884-1Testing Equipm...
- Accessibility Probes
-
Impact Testing
-
IEC60061-3 lamp gauge
-
Electric Safety Tester
-
Environment Test Chamber
-
UL Testing equipment
-
LED Test Instruments
-
Plug, Socket & Switch Te...
-
Oscilloscope
-
Electronic Components Te...
-
Force Meter
-
Tensile Testing Machine
-
Other product
-
Plug and Socket Gauges
Complied Standards & Clauses
IEC60529:2013 “Degrees of protection provided by enclosure (IP code)” IPX5 & IPX6.
Equipment Overview
Samples and Restrictions: Electrical and electronic products, automobiles, motorcycle parts, communication products, household appliances, outdoor lighting and signal devices, etc
Structure: This device is manufactured according to IEC 60529 figure 6.
Application: To verify the protective performance of the enclosure for electronic and electrical products, automobiles, motorcycle parts, household appliances, seals and lamps under water jets at degree IPX5 and IPX6.
Principle: Ensure that the water jet speed reaches the standard required value by controlling the water supply flow, the enclosure is sprayed from all practicable directions with a stream of water from a standard test nozzle as shown in IEC 60529 figure 6.
Use Environment:
Use place: temperature 15-35 ° C, relative humidity 25%-75%, atmospheric pressure 86 ~ 106kpa (860 mbar -1060 mbar), there should be equipped with lighting and waterproof leakage switch (or socket), the ground needs to be flat, and the water intake and drainage function should be good.
Water source: clean water or tap water without impurities, equipped with water cleaning filter.
Technical Parameters
Model
CX-IPX5
CX-IPX6
Nozzle Internal Diameter
Ф6.3mm
Ф12.5mm
Delivery Rate
12.5±0.625L/min, flow meter is adjustable
100±5 L/min, flow meter is adjustable
Distance from Nozzle to Enclosure Surface
2.5~3m
2.5~3m
Core of the Substantial Stream
Circle of approximately 40 mm diameter at 2.5 m distance from nozzle
Circle of approximately 120 mm diameter at 2.5 m distance from nozzle
Test Duration
Likely 1min/m² (minimum: 3 min)
Likely 1min/m² (minimum: 3 min)
Pressure Gauge
0~0.25MPa
0~0.25MPa
Optional
Configure with 0-18L/min rotameter, flexible hose
Configure with 20-120L/min rotameter, flexible hose