CX-118 Crystal Vibration Tester 1HZ~100MHZ
Main features
Measuring range
Binning measurement: according to the center frequency F0 set by the user, automatically binned measurements.
Binning value: Pr1 ~ Pr8 can be set between 1 ~ 999ppm
Cumulative count: Counting Capacity: 0 ~ 109-1 (optional)
Counting mode: Keying, gating or external gating for optional
A channel low-pass filter: -3dB bandwidth approximately is 100kHz
Measurement error
Trigger error: When the measured signal to noise is 40dB, the trigger error is ≤0.3%
gate time
Weight: <1.5kg
Crystal test kit (crystal measuring matcher) Optional:
1
It's using reciprocal counting technique, high accuracy, wide measuring
range, truly equal precision measurement, fast speed measurement,high sensitivity.
2
single-chip microprocessor technology cycle frequency measurement and
intelligent management, making the instrument has high reliability and
excellent performance / price ratio.
3 It's using LSI design, the
use of CPLD devices, instrument components greatly reduced, reliability
has been greatly improved, the average time between failures ≥10000h.
The machine looks nice, small size, light weight, easy to use.
Frequency Measurement: A Channel:1Hz ~ 100MHz;
B channel: 100MHz ~ 1.6GHz (optional)
Period Measurement: A Channel: 10ns ~ 1s
PPM measurement: -9999 ~ 9999ppm
Upper and lower limit measurement: according to the parameters set by the user of upper limit FU, lower limit FL parameters to measure the measured frequency whether exceeds the lower
limit and upper limit value. if exceed, it will be alarm.
quantity of Binning: according to center frequency F0 is divided into 16 stalls around the midpoint
Input characteristics
Input impedance: A Channel: 1MΩ // 40pF
B Channel: 50Ω
Input Coupling: AC
adaptive waveform: sine, pulse wave
Input voltage dynamic range:
A Channel: 30mVrms ~ 250Vp ~ p
B channel: 30mVrms ~ 1Vrms
A Channel Attenuation: × 1 or × 20
The frequency or period measurement error: ± time base error ± trigger error ± LSD 100ns
When: LSD = _× measured frequency (or test period)
Gate time
PPM measurement error: ± time base error ± trigger error ± LSD
When: LSD = (100ns / gate time) ×106ppm
For example: When the gate time = 1s, LSD = 0.1ppm
When the gate time = 0.1s, LSD = 1ppm
counting error: ± 1
Fixed gate: 10ms, 100ms, 1s, 10s four types optional
Adjustable Gate: 50ms ~ 95ms in 10 files, each file interval of 5ms.
Crystal Oscillator
Nominal frequency: 10MHz
Frequency stability: 5 × 10-6 / d
(According to user needs, you can match higher crystal)
Such as: 1 × 10-6 / d, 5 × 10-7 / d, 1 × 10-7/ d, etc.).
FSB standard input
Input frequency: 10MHz
Input amplitude:> 1Vp ~ p sine wave
Display
13 digits 0.4-inch bright LED green, three units of LED Indicator light (MHz, kHz, Hz), GATE indicator, EXT indicator and PPM indicator
Power
Voltage: AC 220V ± 10%
Frequency: 50Hz ± 5%
Power consumption: <8VA
Dimensions: 230 × 250 × 90 (mm)
1Hz-20MHz (comes with machine)
20MHz-40MHz (sold separately),
40MHz-65MHz (sold separately);
65MHz-100MHz (sold separately).