Product Details
  • Product name:IEC60335-1 Leakage Current Tester Electrical Appliance Safety Testing Equipment

  • Product number:CX-2675C3
  • Product manufacturer:Chuangxin
  • Product documentation:
你添加了1件商品 查看购物车
a brief introdction:
IEC60335-1 Leakage Current Tester Electrical Appliance Safety Testing Equipment Product information: ■ Meet the electrical safety general test requirements of IEC60335.1, UL60335.1, GB4706.1, etc. ■Built-in common human body simulation impedances, different simulation impedance standard cards can be selected according to different standards, default come with network as per IEC 60335-1, oth
Details description:

IEC60335-1 Leakage Current Tester Electrical Appliance Safety Testing Equipment

Product information:

■ Meet the electrical safety general test requirements of IEC60335.1, UL60335.1, GB4706.1, etc.
■Built-in common human body simulation impedances, different simulation impedance standard cards can be selected according to different standards, default come with network as per IEC 60335-1, other networks are optional.
■ Upper limit preset, automatic reminder of alarm message, intelligent memory analysis function, system self-check function, automatic protection function.

■ 16*2LCD display

■The instrument has a software calibration function for simplify parameter calibration.

 

Technical Parameters:

Model CX-2675A
Input voltage 220Vac±10%
Input power 50/60Hz±5%
Fuse Fuse 0.5A/250V
Leakage current
Test input voltage 30-300V AC Single phase
Test input current 20A AC MAX
Voltage display range 30-300V AC
Voltage display resolution 1V
Voltage display accuracy ± (2% setting+3V)
Leakage current range 50-6000uA
Leakage current resolution 1uA
Leakage current accuracy ± (2% reading+30uA)
Built-in human network Default as per IEC 60335-1, other networks are optional
Test time range 1.0-2.0-999.9s , resolution 0.1s, set 1s only to test the leakage of firewire
Function parameters
Display 16*2 blue screen character LCD display
Communication Interface RS232(optional)
Calibration method Software calibration
Working environment 0-40℃, 20-80%RH
Dimensions & weight 280mm(W)×89mm(H)×370mm(D), approx. 15kgs
Accessories Power cord × 1, test clip × 2, fuse× 1
 

Calibration required instrument:

1. 50-300V adjustable test power source

2. 50K block resistor

3. Digital multi-meter with a 20mA AC.

 

Calibration preparation:

Set the upper limit current alarm value of the tester SN9620X to the full scale, and the lower limit to 0. The current calibration within the measuring range can be performed and avoid the over current test stop.

 

Calibration connection: