IEC60335-1 clause 30.2 Needle flame Test Method Fire Hazard Testing Apparatus
	
	 
		Product Information:
	 
		The Needle-flame Test Method Fire Hazard Testing Apparatus is designed and manufactured according to the standard requirements of IEC 62368-1 Annex S, IEC60335-1 clause 30.2, Annex E, etc.
	 
		It consists of a Ф0.9mm needle-shaped burner that tilts with the angel of 45°and provide it with butane gas. The fire hazard of the equipment when there is flammule inside the equipment that caused due to the fault condition is assessed by whether the specimen can be ignited or the combustion time and length.
	 
		The Needle Flame Tester has PLC control and 7-inch color touch screen, it is suitable for the research, production and quality testing department of lighting equipment, low-voltage apparatus, household appliance, machine tool electric appliance, electrical machine, electric tool, electronic instrument, electrotechnical instrument, electrical connector, electrical and electronical equipment and other components. It is also suitable for insulating material, engineering plastics or other solid combustion material industry.
	 
		 
	 
		Technical parameters:
	 
		 
	 
		
		
			
	
				 
			
					Applied standard
				 
				
					IEC 62368-1
				 
			
				 
			
					Applied clause
				 
				
					Annex S
				 
			
				 
			
					Working voltage
				 
				
					AC 220V/50Hz
				 
			
				 
			
					Control
				 
				
					PLC
				 
			
				 
			
					Display
				 
				
					7-inch color touch screen
				 
			
				 
			
					Timing device
				 
				
					9999X0.1S
				 
			
				 
			
					Combustor
				 
				
					Inner boreφ0.5mm ± 0.1mm, OD ≤φ0.9mm, L ≥ 35mm, stainless steel
				 
			
				 
			
					Combustion angle
				 
				
					tilt 45° (testing) or vertical (when adjust the height of the flame)
				 
			
				 
			
					Height of the flame
				 
				
					12±1mm adjustable (with flame height gauge)
				 
			
				 
			
					Gas category
				 
				
					95% butagas (can use the bottled lighter gas)
				 
			
				 
			
					Range of temperature test
				 
				
					0~1000℃
				 
			
				 
			
					Flame warming requirement
				 
				
					From 100°to 700°, time for standard values within 23.5S±1S
				 
			
				 
			
					Temperature thermocouple
				 
				
					φ0.5 armour nickel-chromium/nickel aluminum wire K-Thermocouple
				 
			
				 
			
					Work shop
				 
				
					0.5 cube, stainless steel case, black yogin background
				 
			
				 
			
					Testing process
				 
				
					Test procedure automatic control, independent air draft
				 
			
				 
			
					Volume size adjustment
				 
				
					Flowmeter adjustment
				 
			
				 
		
	
					Equipment size & weight
				 
				
					1100mm* 550mm* 1100mm, 120KGS
				 
			 
	
	 
	
 
     
     
                             
                             
                             
                             
                             
                             
                             
                            