IEC 62368 Test Equipment
- IEC60529 IP CODE TESTING...
-
IEC60335-1 Testing equip...
-
Flammability Test Chambe...
-
IEC60884-1Testing Equipm...
- Accessibility Probes
-
Impact Testing
-
IEC60061-3 lamp gauge
-
Electric Safety Tester
-
Environment Test Chamber
-
UL Testing equipment
-
LED Test Instruments
-
Plug, Socket & Switch Te...
-
Oscilloscope
-
Electronic Components Te...
-
Force Meter
-
Tensile Testing Machine
-
Other product
-
Plug and Socket Gauges
IEC60335-1
Product information:
Standads & Clauses:
IEC60884-1:2006
IEC60335-1:2004
IEC60065:2005clause 15.4.1 and figure 11
Test process:
Insert the device into a fixed socket conforming to this standard. The socket is rotated 8 mm behind the socket joint face by a horizontal axis through the axis of the live socket contact and parallel to the joint face.
The additional torque that must be applied to the socket to maintain the joint in the vertical plane shall not exceed 0.25 Nm.
Technical Parameters:
Test Station
Single
Specimen Eccentricity
Distance from the contact surface and the Axis of the surface:8mm
Balancing Arm
L:50-260mm
Weight
2.5N, can achieve 0.25Nm to 0.4Nm torque force
Torque Calculation Method
G×L(such as 0.25N.m,use 2.5N weights and 100 mm arm)
Configure
One of each universal socket (suit for BS plug), UL socket, European socket