IEC 62368 Test Equipment
- IEC60529 IP CODE TESTING...
-
IEC60335-1 Testing equip...
-
Flammability Test Chambe...
-
IEC60884-1Testing Equipm...
- Accessibility Probes
-
Impact Testing
-
IEC60061-3 lamp gauge
-
Electric Safety Tester
-
Environment Test Chamber
-
UL Testing equipment
-
LED Test Instruments
-
Plug, Socket & Switch Te...
-
Oscilloscope
-
Electronic Components Te...
-
Force Meter
-
Tensile Testing Machine
-
Other product
-
Plug and Socket Gauges
IEC60335-1 AC/DC High Voltage Withstand & Insulation Resistance Testing Equipment
Product information:
■Meet the test requirements of general electrical safety standards such as IEC60335.1, UL60335.1, GB4706.1, etc.
■ Up to 100 groups of test condition memory, model of each group can be set, easy to find, test data can be saved via USB(optional)
■ Voltage ramp-up and ramp-down functions to meet the requirements of new industry standards;
■ Breakdown current upper and lower limit preset, intelligent judgment;
■ Digital closed-loop feedback control mode, automatic voltage regulation mode, automatic correction of output voltage/current, and not affected by the external power grid, ensuring the accuracy of the test
■ High-definition LCD display and simple panel operation
Technical Parameters:
Model | CX-7112 |
Test Contents | AC and DC withstand voltage, insulation resistance |
Data storage method | USB (optional) |
External interface | Alarm LAMP, PLC, RS-232 |
AC withstand voltage | |
Output voltage setting range / accuracy |
AC 200~5000V ±(1.5%×setting+5digits) |
Breakdown current measurement range / accuracy |
0.10~100.0mA ±(1.5%×setting+5digits) |
Breakdown current preset alarm range |
Upper limit :0.1~100.0mA; Lower limit :0.00~5.00mA |
Test time range / resolution | 1~300s 1s/step |
DC withstand voltage | |
Output voltage setting range / accuracy | DC 200~5000V ±(1.5%× setting +5 digits ) |
Breakdown current measurement range / accuracy | 0.10~10.00mA ±(1.5%×display+5 digits) |
Breakdown current preset alarm range | Upper limit: 0.10~10.00mA; lower limit: 0.00~5.00mA |
Test time range / resolution | 1~300s 1s/step |
Insulation resistance | |
Output voltage setting range / accuracy | DC500/1000V ±(1.5%× reading +5 digits ) |
Insulation resistance measurement range / accuracy |
1~2000MΩ: ≤100MΩ:± (5%×display+3 digits ) >100 MΩ:± (8%× display +8 digits) |
Insulation resistance alarm setting range |
Upper limit: 0 ~ 2000MΩ; lower limit: 1 ~ 2000MΩ |
Test time range / resolution |
1~300s 1s/step |
Equipment dimensions | 435MM(W)*150MM(H)*550MM(D) |
Equipment weight | Approx. 30KGS |
Equipment accessories | Power cord*1, high voltage probe*1, test wire*1, fuse*1 |
External Wire Connection:
First confirm the power supply standard, AC 220V±10%,50Hz±5%,single-phase; the fuse standard: 5A,slow-blow. Note: terminals on the power supply connection box are marked as: output L, input N, GBI+,GBU+, earth connection clamps are marked GBU-,GBI-, connect the corresponding terminals on the rear panel when use.